Model |
Specs |
Image (click for larger) |
Model 571004
Thermocouple Transmitter 2-Wire
LCD Indicating |
INPUT RANGE:
T/C Type “J” 0 to 1300ºF Max.
T/C Type “K” 0 to 2400º Max.
T/C Type “T” 0 to 700º Max.
T/C Type “E” 0 to 1800º Max.
OUTPUT:
4 to 20mA DC into 600? @ 24 volts
DISPLAY:
0.5” High., 3 ½ Digit LCD
Accuracy: ±0.2% of Span
Linearity: ± 2% Nominal Selected Ranges
Power: 12 to 36 Volts DC, 24 Volts DC Nominal
Compensated Temperature Range: -20ºF to +140ºF Zero and Span Effect: Less Than .02%/ºF
HOUSING:
NEMA 4/7/9, Explosion Proof
CL1, GR-B, C, D; CL2, GR-E & G
The 571 linearized digital indicating thermocouple transmitter measures thermocouple voltages as a function of temperature and provides both linearized 4 to 20 mA DC output loop signal and 3 ½ digit LCD indication of process temperature. Optional features include surface and pipe clamp mounting. Close coupled mounting shown. |
|
Model 571006
Thermocouple Transmitter 2-Wire |
INPUT:
Thermocouple, All Standard
Calibrated Span: 5mVDC Min.
Types: Standard J, K, T, E
Impedance: 500K? Min.
OUTPUT:
4 to 20 mA DC, Two Wire, Linearized
Accuracy: ±0.20% of Span
Power: 24VDC Nominal, 22 Min. 48VDC Max.
Ambient Operating Temperature: -20ºF to +140ºF
HOUSING:
NEMA 4/7/9, Explosion Proof
CL1, GR-B, C, D; CL2, GR-E & G
Copper Free Aluminum with “Safety” Blue Finish
The 571006 thermocouple-to-current transmitter is for in-tank and pipe applications requiring sensor insertion into the media The 571006 is supplied in eight different “U” lengths, covering most applications. Sensor isolation is tested to 500VDC greater than100 M Ohm. |
|
Model 577004
RTD Transmitter 2-wire
LCD Indicating |
INPUT RANGE
-300 to +750ºF, 100Ω Platinum
Span: 50ºF Min. (30ºF optional)
OUTPUT: 4 to 20mA DC (Two Wire) Linearized
Accuracy: ±0.25% of Span
Loop Resistance Max. 600? @ 24V DC
Power:12 to 36VDC, 24VDC Nominal
Ambient Operating Temp:-20ºF to +140ºF
Display: 0.5” High., 3 ½ Digit LCD
Indexable in 90º Increments
Annuciator: Auto-Polarity, Over range
Blanking, Jumper Selectable “F”, “C” and Decimal Point
HOUSING:
NEMA 4/7/9, Explosion Proof
CL1, GR-B, C, D; CL2, GR-E & G
Copper Free Aluminum with “Safety” Blue Finish
The 577004 RTD Transmitter provides both local 3 ½ digit LCD indication and 4 to 20 mA DC two-wire transmission to remote instruments. Optional features include surface and pipe clamp mounting. Close coupled Mounting Shown. |
|
Model 577066
RTD Transmitter 2-wire |
INPUT RANGE:
-300ºF to +900ºF, 100Ω Platinum
Span: 50ºF Min. (30ºF Optional)
OUTPUT:
4 to 20mA DC (Two Wire) Linearized
Accuracy: ±0.25% of Span
Loop Resistance Max. 600Ω @ 24VDC
Power: 12 to 36VDC, 24VDC Nominal
Ambient Operating Temp: -20ºF to +140ºF
CSA Class I, Groups A, B, C and D; Class II, Groups E, F, and G; Class III
The 577066 RTD transmitter is for in-tank and pipe applications requiring sensor insertion into the media. The 577066 is supplied in eight standard “U” Lengths, covering most applications. Sensor isolation is tested to 100VDC. |
|
Model 577506
RTD Transmitter 2-wire |
INPUT:
100 Ohm Platinum RTD
Range: -300ºF to 1300ºF(-190º to 710ºC)
Degrees C/F switch selectable
RTD Sensor Current: 400µA
Span: switch selectable, 30ºF Min., 1200ºF
(20ºC Min., 700ºC Max.)
Zero Suppression: switch selectable
-300ºF to 970ºF, (-190ºC to 710ºC)
Output adjustment +/-5% Typ.
Accuracy: ±0.05% of Span Typ.
Ambient Effect :±0.002% of Span/ºF Typ.
OUTPUT:
Output: 4 to 20mA DC into 600Ω @ 24VDC
Power:12 to 36VDC 2 Wire Loop Powered
Process Connection: ½” NPT
Compensated Temperature Range: -40ºF to 160ºF
Operating Temperature Range: -20ºF to +160ºF
Update Time: 20 Readings/Sec.
Response Time: 3.2 Seconds (input to output max.)
Up/Down Scale Break: Switch Selectable
Sensor: 100Ω platinum 3 wire
(±0.1% of 100 Ohm @ 0ºC)
The 577506 RTD Temperature Transmitter is designed for close-coupled, integrally-mounted applications. Using microcontroller-based circuitry, the 577506 senses resistance changes as a function of temperature and provides an extremely stable and accurate 4 to 20mA DC loop output. Field rangeability and user selectable features allow a single device to satisfy virtually all temperature applications. Re-calibration or programming is done in seconds using standard hand tools. No soldering or component changes are necessary. The transmitter is housed in a gasketed, explosion-proof enclosure. The enclosure is CSA and UL approved for Class I, Groups C& D, Class II, Groups E, F, & G, and Class III locations. |
|
Model 801066
Thermocouple Transmitter 2-wire |
TECHNICAL SPECIFICATIONS:
Thermocouple Inputs: J, K, N, E, T Full Range, ungrounded recommended
Output Range: 4 to 20mADC
Operating Temp. Range: -40ºF to 160ºF
Temp. Drift: ±0.015% of Span/ºF, Typical
Power and Load: 12 to 36VDC
Accuracy: ±0.2%, Typical @ 72ºF
Max Load Resistance: (Vsupply-8)/.020
The Model 801066 loop powered thermocouple transmitter converts thermocouple signals to a linearized 4 to 20mA current. The input type, range, and up/down scale break are programmed at the factory. Optional general purpose enclosure available. |
|
Model 807066
RTD Transmitter 2-wire |
TECHNICAL SPECIFICATIONS
Input Range: -300ºF to +900ºF
RTD Element: 100? Platinum
Span: 100ºF Min, Typical
Output: 4 to 20mA DC, Linearized
Accuracy: ±0.15% Typical, of Span; not including RTD
Loop Resistance Maximum: 600? @ 24VDC, 4 to 20mA DC
Power: 24VDC, 9VDC Minimum to 36VDC Max.
Ambient Operating Temp: -20ºF to +140ºF
Electrical Connections: 5 Position Terminal Block
Ambient Effect: ± 0.02% of Span/ºF
The Model 807060 is a “two wire” temperature transmitter which measures resistance changes as a function of temperature. The 100? RTD temperature sensor resistance is linearized and converted to a temperature proportional 4 to 20mA DC current. |
|
Model |
Specs |
Image (click for larger) |
511xxx |
Pressure to Current |
Pneumatic Instrument |
512xxx |
Current to Pressure |
Pneumatic Instrument |
611000 |
Pressure to Voltage/Current DIN Rail Mount |
Pneumatic Instrument |
612xxx |
Current to Pressure/Voltage |
Pneumatic Instrument |
568xxx |
AC Voltage |
Two-wire Isolated Transmitter |
571xxx |
Thermocouple |
Two-wire Isolated Transmitter |
572xxx |
DC Millivolt |
Two-wire Isolated Transmitter |
596xxx |
AC Current |
Two-wire Isolated Transmitter |
573xxx |
DC Current |
Two-wire Isolated Transmitter |
574xxx |
DC Voltage |
Two-wire Isolated Transmitter |
576xxx |
Slide Wire |
Two-wire Isolated Transmitter |
577xxx |
RTD |
Two-wire Isolated Transmitter |
578xxx |
Tachometer |
Two-wire Isolated Transmitter |
523000 |
AC Current |
Four-wire Isolated Transmitter |
618xxx |
Tachometer, DIN Railmount |
Options: Alarms, Open Circuit Input |
505000 |
505 Manual Loading Station |
Manual Control of Loop |
540xxx |
540 Thermocouple |
Signal Alarm |
541xxx |
541 DC Current |
Signal Alarm |
542xxx |
542 DC Millivolt |
Signal Alarm |
543xxx |
543 DC Voltage |
Signal Alarm |
544xxx |
544 RTD |
Signal Alarm |
545xxx |
545 AC Voltage |
Signal Alarm |
547xxx |
547 Tachometer |
Signal Alarm |
548xxx |
548 Slidewire |
Signal Alarm |
549xxx |
549 Strain Gauge |
Signal Alarm |
807xxx |
RTD Transmitter 2-Wire |
Head Mount, Explosion Proof, NEMA |
815000 |
Loop Isolator 2-Wire |
Head Mount, Explosion Proof, NEMA |
571004 |
Thermocouple, Indicating |
Close Coupled Temperature Transmitter |
571006 |
Thermocouple, Non Indicating |
Close Coupled Temperature Transmitter |
577004 |
RTD Indicating |
Close Coupled Temperature Transmitter |
577066 |
RTD Non-Indicating |
Close Coupled Temperature Transmitter |
577506 |
RTD Field Selectable |
Close Coupled Temperature Transmitter |
680000 |
AC TO DC Power Supply |
115/230V AC to 24V DC @ 250mA DC DIN Rail Mount 24V DC |
681000 |
AC TO DC Power Supply |
115/230V AC to 24V DC @ 630mA DC DIN Rail Mount 24V DC |
580000 |
AC TO DC Power Supply |
115/230V AC to 24V DC @ 125mA NEMA 4 |
580002 |
AC TO DC Power Supply |
115/230V AC to 24V DC @ 125mA NEMA 7/9 |
WE-100 |
AC TO DC Power Supply |
115V AC (optional 230) to 24V DC (optional 5 to 32V DC) @125mA DC |
WE-103 |
AC TO DC Power Supply |
115V AC to 5, 12, 15, 24V DC @ 2.4, 1.0, 0.8 & 0.56 A DC |
WE-104 |
AC TO DC Power Supply |
115V AC to 5 to 24V DC 1A to 500mA DC |
WE-107 |
AC TO DC Power Supply |
115V AC 5 to 24V DC 1.0A to 300mA DC |
WE-108 |
AC TO DC Power Supply |
115V AC 5 to 24V DC 2.4A to 0.56A DC |
WE-109 |
AC TO DC Power Supply |
115V AC 5 to 24V DC 6.0A to 1.5A DC |
WE-110 |
DC TO DC Power Supply |
115V AC 5 to 24V DC 6.0A to 1.5A DC |
WE-111 |
DC TO DC Power Supply |
12V DC to 62V DC to 5 to 24V DC |
WE-114 |
AC TO DC Power Supply |
115V AC to 24V DC 250mA Wall Mount |
WE-117 |
AC TO DC Power Supply |
115V AC to 5 to 24V DC @ 12.5 to 3.5A DC |
WE-118 |
AC TO DC Power Supply |
115V AC to 5 to 24V DC @ 25 to 5A DC |
WE-119 |
AC TO DC Power Supply |
115V AC to 5 to 24V DC @ 36 to 7.5A DC |
WE-120 |
AC TO DC Power Supply |
115V AC to 5 to 24V DC @ 50 to 11A DC |
586000 |
LCD Digital Meter |
Digital Meter LCD Loop Powered 3 1/2 Digit NEMA 4X |
594000 |
LCD Digital Meter |
Digital Panel Meter LCD Loop Powered 3 1/2 Digit |
594001 |
LCD Digital Meter |
Digital Panel Meter LCD Loop Powered 3 1/2 Digit NEMA 4X |
594002 |
LCD Digital Meter |
Digital Panel Meter LCD Loop Powered 3 1/2 Digit Explosion Proof |
594004 |
LCD Loop Powered, Rate Surface Panel/Mount |
Digital Meter LCD Loop Powered 3 1/2 Digit NEMA 4/7/9 Explosion Proof |
598000 |
LED Indicator |
Digital Panel Meter LED 3 1/2 Digit Panel Mount |
598001 |
LED Indicator |
Digital Panel Meter LED 3 1/2 Digit NEMA 4X |
598002 |
LED Indicator |
Digital Panel Meter LED 3 1/2 Digit Explosion Proof NEMA 7/9 |
|